HIGH TURBIDITY
MEDIUM TURBIDITY
0.2 MICRON
SPECTRA PERISTALTIC PUMP
PEGASUS PERISTALTIC PUMPS
 

contact manuals rentals HOME

 

state-of-the-art

At the heart of each multiparameter AQUAPROBE™ is a state-of-the-art, high speed microprocessor coupled to a multi-channel, 16 bit, high precision Analogue to Digital converter. This combination allows fast, accurate control and measurement of the data being provided by the individual electrodes. Up to 4 electrodes can be mixed and matched during manufacture in order to provide ten different models of the probe.

All ten versions are supplied with 3m cable and accessories as detailed in the product brochure.

PARAMETER
AQUAPROBE MODEL NUMBER
AP-1000
AP-900
AP-800
AP-700
AP-600
AP-500
AP-400
AP-300
AP-200
AP-100
Turbidity
SF
SF
SF
SF
SF
SF
Dissolved Oxygen
(Galvanic)
SF
SF
SF
SF
SF
Dissolved Oxygen
(Optical)
SF
SF
Conductivity
SF
SF
SF
SF
SF
SF
SF
TDS
SF
SF
SF
SF
SF
SF
SF
Resistivity
SF
SF
SF
SF
SF
SF
SF
Salinity
SF
SF
SF
SF
SF
SF
SF
Seawater SG
SF
SF
SF
SF
SF
SF
SF
PH
SF
SF
SF
SF
SF
SF
SF
SF
ORP
SF
SF
SF
SF
O
O
O
O
Temperature
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
Depth
SF

 

SF = STANDARD FUNCTION

O = OPTIONAL ELECTRODE AVAILABLE TO PREFORM THIS FUNCTION

= N/A

 

features

  • waterproof plug assembly
  • heavy guage marine grade aluminum removable protective sleeve—ensures the individual measurement electrodes are kept safe, even in the harshest environments
  • 1.65" OD (42mm) — designed to fit comfortably into pipes, 2" wells and bore-holes
  • each probe body is completely resin filled and fully waterproof for indefinite immersion
  • threaded stem (and nut) provided at the top of the probe allows bracket or extension pole mounting

Extension cables are available in lengths of 5m (16'), 10m (32') & 30m (98'):

  • Complete with in-line sockets
  • Stackable to a total length of 100m (330')

 

calibration

Every AQUAPROBE™ is delivered fully calibrated and ready to use out of the box. All calibration data is stored on-board the probe so that probes and meters can be mixed and matched without any problems.

SEE VIDEO

recalibration

Recalibration is simple. For regular field use, AQUAREAD™ provides an all-in-one calibration solution, RAPIDCAL™, allowing easy one step calibration. Full calibration of each individual electrode is also straightforward, by following simple instructions on the AQUAMETER™.

IMPORTANT!

The sleeve on the Aquaprobe forms an integral part of the measurement system for both EC and turbidity. The Aquaprobe will not function properly without both halves of the sleeve fitted.

Aquaprobes™ get a new sleeve!

All Aquaprobes are now fitted with a new two-part sleeve. The upper half of the sleeve is attached to the Aquaprobe body in the same way as before, but the lower half of the sleeve can be unscrewed by hand to allow easy access to the electrodes for cleaning and maintenance without the need for re-calibration. The new two-part sleeve is completely compatible with all existing probes and flowcells, and can be retrofitted in just a few minutes. Replacement two-part sleeves are available.

IMPORTANT!

The sleeve on the Aquaprobe forms an integral part of the measurement system for both EC and turbidity. The Aquaprobe will not function properly without both halves of the sleeve fitted.

NEW! AP-1000 AQUAPROBE™

includes optical dissolved oxygen sensor & depth measurement

AP-1000 PARAMETER
AP-1000
AP-900
Turbidity
SF
SF
Dissolved Oxygen
(Optical)
SF
SF
Conductivity
SF
SF
TDS
SF
SF
Resistivity
SF
SF
Salinity
SF
SF
Seawater SG
SF
SF
PH
SF
SF
ORP
SF
SF
Temperature
SF
SF
Depth
SF
 

 

The new AP-1000 Aquaprobe features Aquaread's nano engineered Optical Dissolved Oxygen (DO) sensor and depth measurement.

 

SF=Standard Function

 

also available: AP-900

The AP-900 Aquaprobe™ is identical to the AP-1000 but without depth.

 

optical DO advantages

  • Membrane free DO measurement means no fouling
  • Long term stability means infrequent calibrations
  • No oxygen consumption means no flow of water is required
  • No electrolyte or membrane means very low maintenance

optical DO specifications

  • Range............... 0 – 500.0% / 0 – 50.00 mg/L
  • Resolution......... 0.1% / 0.01mg/L
  • Accuracy............ 0 – 200% ± 1% of reading or 200% – 500% ± 10% of reading

 

depth and level logging

  • Depth is measured by an internal pressure sensor and automatically corrected against temperature and salinity
  • The depth feature can also be used to monitor changes in level when the probe is left logging data

depth specifications

  • Range....................... 0 – 30 Meters (0-100 Ft)
  • Resolution..................0.01M (0.4")
  • Accuracy.................... +/- 0.1M (4")

calibration

Every AQUAPROBE™ is delivered fully calibrated and ready to use out of the box. All calibration data is stored on-board the probe so that probes and meters can be mixed and matched without any problems.

recalibration

Recalibration is simple. For regular field use, AQUAREAD™ provides an all-in-one calibration solution, RAPIDCAL™, allowing easy one step calibration. Full calibration of each individual electrode is also straightforward, by following simple instructions on the AQUAMETER™.

IMPORTANT!

The sleeve on the Aquaprobe forms an integral part of the measurement system for both EC and turbidity. The Aquaprobe will not function properly without both halves of the sleeve fitted.

 

 

 

AQUAPROBES™

multi parameter

The real star of the AQUAREAD™ Water Quality Testing System is the multi parameter AQUAPROBE™. Available in ten different versions to cover everything from basic pH testing right through to comprehensive water analysis, these probes are built from high quality marine grade aluminum and stainless steel to withstand rough treatment in the harshest environments.

 
METERS
 